Starting the trace, Starting, Trace – Yaskawa FSP Amplifier FlexWorks User Manual

Page 54

background image

Operating the FSP Amplifier Using FlexWorks

54

5. Click Up one zoom level to view the previous zoom level.

Figure 28: Chart Zoom Feature

4.7.3. Starting the Trace

To start a trace:

1. In the Chart main window, click Start Trace .

A message Waiting for trigger and data collection completion
is displayed.

2. To cancel the trace, click Start Trace again. Otherwise,

click Run to run the program.
When the conditions are met and the trigger is applied, a

message Uploading data is displayed.

3. Click Cancel if you want to halt the data sampling process,

otherwise wait until the process ends.
The Chart main window is displayed once the specified data
has been obtained.

N

OTE

:

1. Sometimes the trigger cannot be detected in under 2 ms due
to the relationship of the detection period.
2. If the sampling time is increased, FlexWorks may continue to
wait for the trigger even after the trigger has been applied.

FlexWorks waits because data for the sampling time is saved in
the FSP Amplifier after the trigger has been applied.