ECAM_DISENGAGE
G
ROUP
ECAM
S
YNTAX
ECAM_DISENGAGE
O
P
. C
ODE
122
M
ODES
Program, Sequential
D
ESCRIPTION
Terminates ECAM motion. Motion only stops once the
current profile has been completed. To stop the motion
immediately, use the STOP_EX command instead. See
4.9.13.2, ECAM_DISENGAGE.
E
XAMPLE
ECAM_ENGAGE 3, CYCLIC
DELAY 10000
ECAM_DISENGAGE
E
XAMPLE
E
XPLANATION
ECAM profile number 3 will be followed for 10 seconds.
After 10 seconds, the ECAM motion will continue until
the current profile has been completed, irrespective of
how many cycles have already been completed. ECAM
motion will then stop.
S
EE
A
LSO
ECAM_ENGAGE, ENGAGE_VIRTUAL_AXIS, STOP_EX
Variables: ECAM_Master_scale_den,
ECAM_Master_scale_num, ECAM_Slave_scale_den ,
ECAM_Slave_scale_num, ECAM_Offset, ECAM_Shift
ECAM_Master_profile_position,
ECAM_Slave_profile_position