INPUT_CASE
G
ROUP
Program Flow Control
S
YNTAX
INPUT_CASE
O
P
. C
ODE
97
M
ODES
Program
R
ANGE
– 1 to 0x00FFFFFF
– 0 to 0x00FFFFFF
D
ESCRIPTION
The program flow is conditional on the state of a
combination of digital inputs. If the condition is True,
the next program line is executed. Otherwise, the
next program line is skipped.
is used to define which inputs are
detected and which are ignored (1 - detected, 0 -
ignored). For example, if is set to 5 (in
binary: 0101) only inputs 0+2 are checked; the rest
are ignored.
Input Mask
…. 0 0 0 1 0 1
defines the logical combination to be
detected as True. For example, if is
set to 4 (in binary: 0100), True means input 0 OFF,
input 1 OFF, input 2 ON and input 3 OFF.
Input State
…. 0 0 0 1 0 1
S
YNTAX
A
RGUMENTS
Input mask
Input mask (decimal value). Defines
which inputs are detected and which
are ignored:
Setting Code
Ignore the input
0
Check the input
1
Serial