Yaskawa FSP Amplifier FlexWorks User Manual
Page 229

Parameter Reference
229
Pn500
Positioning Completed Width
ref. units
0-250
7
5.5.3
Pn501
Zero Clamp Level
rpm
0-10000
10
5.4.3
Pn502
Rotation Detection Level
rpm
1-10000
20
5.5.5
Pn503
Speed Coincidence Signal
Output
Width
rpm 0-100 10 5.5.4
Pn504
NEAR Signal Width
ref. units
1-250
7
5.5.8
Pn505 Overflow
Level
256 ref.
units
1-32767 1024
6.2.1
Pn506
Brake Reference Servo OFF
Delay
Time
10 ms
0-50
0
5.4.4
Pn507
Brake Reference Output Speed
Level
rpm 0-10000
100 5.4.4
Pn508
Timing for Brake Reference
Output
during Motor Operation
10 ms
10-100
50
5.4.4
Pn509
Momentary Hold Time ms
20-1000
20
5.5.9
Pn50A*
Input Signal Selections 1
—
—
2100
5.3.3
Pn50B*
Input Signal Selections 2
—
—
6543
5.3.3
Pn50C*
Input Signal Selections 3
—
—
8888
5.3.3
Pn50D*
Input Signal Selections 4
—
—
8888
5.3.3
Pn50E*
Output Signal Selections 1
—
—
3211
5.3.4
Pn50F*
Output Signal Selections 2
—
—
0000
5.3.4
Pn510*
Output Signal Selections 3
—
—
0000
5.3.4
Pn511
Reserved parameter (Do not
change).
— —
— —
Sequence Parameters
Pn512*
Reserved parameter (Do not
change.)
— —
— —
Pn580
Zero clamp level
mm / s
0-5000
10
—
Pn581
Motion detection level
mm / s
1-5000
20
—
Pn582
Speed coincidence signal output
width
mm / s
0-5000
10
—
Linear Motor
Sequence
Parameters
Pn583
Brake reference output speed
level
mm / s
0-5000
100
—
Pn600
Regenerative Resistor
Capacity**
10 W
0 to
capacity
***
0 5.6.1
Other
Para-
meters
Pn601
Reserved parameter (Do not
change.)
— —
— —
*
After changing this parameter, cycle the main circuit and control power supplies to enable the new settings.
**
Normally set to "0". When using an external regenerative resistor, set the capacity (W) of the regenerative resistor.
*** The upper limit is the maximum output capacity (W) of the servo amplifier.
Category
Parameter
Number
Name
Unit
Setting
Range
Default
Setting
Reference