Editing a profile, Inserting additional profile segments, Deleting – Yaskawa FSP Amplifier FlexWorks User Manual
Page 70: Segment, Editing values in the position setting table

Operating the FSP Amplifier Using FlexWorks
70
5. Click Open in the Cam Profile File area.
The Open Cam Profile dialog box is displayed.
6. Select the file to open, and click Open.
The segments of the opened profile are listed in the Position
Setting tab.
4.9.6. Editing a Profile
4.9.6.1. Inserting Additional Profile Segments
To insert a segment between existing segments in a
profile:
1. Click any field in the row of the segment before which the
new segment should be inserted.
2. Click Insert.
A new line is inserted.
3. Enter the required data to define the new segment.
4.9.6.2. Deleting a Segment
To delete a segment:
1. Click any field in the row of the segment that is to be
deleted.
2. Click Delete.
0.
The selected segment is deleted.
4.9.6.3. Editing Values in the Position Setting Table
To edit an entered value:
1. Click the field that you would like to change.
2. Enter the new value. The value is changed, and the table
values are automatically updated.
If the value of a Master End position is changed, all
subsequent Master End values are automatically adjusted to
maintain the size of the segments as they were before the
change. Changing a Master End value therefore affects only
the size of the segment that the point ends. (The Master
Start values are also updated to match the revised Master
End values.)
Changing the value of a Slave End position does not result in
subsequent Slave End values being updated – only the next
Slave Start value is updated.