Serial Interface Protocol

211

V1 – V8

Description: Variable value.

Answer Field for GET_PAR Command

C1 C2 I

NX

_1 I

NX

_2 I

NX

_3 I

NX

_4 V1 V2 V3 V4

Where:

C1

AND

C2

Description: Response message Operational Code. C1 and C2 hold

the same Operational Code as the original message.

I

NX

_1-

I

NX

_4

Description: Parameter number reference list in Chapter 8,
Parameter Reference.

V1 – V4

Description: Variable value.

Answer Field for GET_VERSION Command

C1 C2 V1 V2 V3 V4

Where:

C1

AND

C2

Description: Response message Operational Code. C1 and C2 hold
the same Operational Code as the original message.