Error Messages
223
C
ODE
M
ESSAGE
D
ESCRIPTION
speed.
133
Final target too big
If a new target position is sent
with a MOVE_H command, an
overflow may occur. The motor
must first be stopped and only
then can the motion continue.
134
Speed too low.
The speed is too low for specified
motion.
135
SET_VAR: Variable value out of
range
The variable value in command
SET_VAR is out of range.
136
Program flow error
Program flow error: RETURN
without CALL or CALL nesting too
deep.
137
Moving time is too short with
present profile Jerk time
The specified jerk time exceeds
the maximum of 64000 ms.
139
Home sensor not defined
The Home sensor is not defined.
Refer to the HOME_SW and
HOME_SW_C commands in this
manual.
140
Motion cannot be executed while
CONTROL_OFF
The motion cannot be executed
while the motor is disabled. Make
sure the motor is enabled
(CONTROL_ON) before issuing
the motion command.
141
TORQUE LIMITS: Invalid torque
limits
The maximum torque limit is
smaller than the minimum torque
limit.
142
Invalid or duplicated label
The label number is either zero or
greater than the maximum line
number.
143
Invalid input number
The input referred to in the
command is not defined as an
event.
144
Invalid output number
Invalid output index in the
SET_OUTPUT command.
146
Auto-tuning already in progress
The Auto-tuning process is
already in progress. It cannot be
restarted until the process ends.
149
Unable to switch CONTROL_ON