beautypg.com

Table 20: home switches – Yaskawa FSP Amplifier FlexWorks User Manual

Page 236

background image

Parameter Reference

236

Parameter

Digit

Place

Name

Setting

Description

Default
Setting

0

/SPD-D Signal
Mapping
(Internal Set Speed
Selection)

0-F

Same as above.

8: OFF

1

/SPD-A Signal
Mapping
(Internal Set Speed
Selection)

0-F

Same as above.

8: OFF

2

/SPD-B Signal
Mapping
(Internal Set Speed
Selection)

0-F

Same as above.

8: OFF

Pn50C

3

/C-SEL Signal Mapping
(Control Mode
Switching)

0-F

Same as above.

8: OFF

0

/ZCLAMP Signal
Mapping
(Zero Clamping)

0-F

Same as above.

8: OFF

1

/INHIBIT Signal
Mapping (Disabling
Reference Pulse)

0-F

Same as above.

8: OFF

2

/G-SEL Signal
Mapping
(Gain Switching)

0-F

Same as above.

8: OFF

Pn50D

3

(Reserved)

0-F

Same as above.

8: OFF

N

OTE

:

When Pn50A.0 is set to 0 for the FSP Amplifier, only the
following modes are available: Pn50A.1=7, Pn50A.3=8, and
Pn50B.0=8.

8.4. Table 20: Home Switches

Table 20: Home Switches

Parameter

Digit

Place

Name

Setting

Description

Default
Setting

0

Home switch input

0-F

Same as Pn50A.1

8: OFF

1 Reserved

0

2 Reserved

0

Pn2C7

3 Reserved

0