Serial Interface Protocol

214

MOVE Command

Example of response message to MOVE <600> <1000> command
(600uu in 1000 ms), of axis 0 in Sequential mode, with message
identification of 0x96 when control is off. Because a motion cannot
be executed when CONTROL_OFF, fault 0x8C occurs.
Master Message Format:

N

A

M I

D

1 I

D

2 C1 C2 V1 V2 P1 P2 P3 P4 P5 P6

N 0

B 9 6 7 1 0 0 0 0 0 0 0 2

P7 P8 P9 P10 P11 P12 P13 P14 P15 P16 S1 S2

5

8

0

0 0 0 0 3 E 8 A

9

Response Message Format in case of fault:

CR N

A

M

I

D

1 I

D

2 F1 F2 SW1 SW2 SW3 SW4

CR

N

0

1

9

6

8

C

0 4 3 3

S1 S2 CR

A 6 CR

Where:

A = 0

Axis number 0

m = 1

Response type is acknowledged with Fault.

ID1 = 9; Id2 = 6

Because of fault message identification, Id1

and Id2 contain the same value as master
message identification.

F1 = 8; F2 = C

Fault code.

SW1=0; SW2=4;
SW3=3; SW4=3

Shows FSP Amplifier status. No emergency,
no fault (Status word fault only represents
FSP Amplifier hardware faults marked as
A.##), control off and in position (see
Chapter 10, List of Status Word Bits).

S1=A; S2=6

0x100–(0x01+0x96+0x8C+0x04+0x33)=
0xA6.