Error Messages
224
C
ODE
M
ESSAGE
D
ESCRIPTION
150
Command argument value is out
of range
151
Positive Over Travel
152
Negative Over Travel
153
Can't perform motion. 
Reconfigure New move enable 
digital input (Pn2D1.1) or use 
Override_new_move_enable. 
154
ECAM Table is not ready
Table sending was not completed 
(or not even started). Therefore 
ECAM motion cannot be 
executed. 
155
ECAM - Profile ID does not exist
Trying to engage to non-existent 
profile ID (number). 
156
Max slave or master 
displacement in profile is 2^31 
after scaling and gearing 
Max slave or master displacement 
in profile is 2^31 after scaling 
and electronic gearing. 
157
ECAM Master overflow
When the time to accomplish the
profile plus shift is smaller than 
one servo cycle (125 
μs).
159
INT_RETURN command is not in 
interrupt service routine 
162 System
alarm.
163 System
alarm.
164 System
alarm.
165
Pulse train counter overflow.
166
Encoder counter error.
255
Fault message buffer full. In case 
FAULT_MANAGER is activated, 
use the FAULT_MESSAGE_CLEAR 
command to clear the messages.
 
 