Setting parameters online, Setting parameters offline, Programming the fsp amplifier – Yaskawa FSP Amplifier FlexWorks User Manual
Page 37: Setting parameters online 4.3.3

Operating the FSP Amplifier Using FlexWorks
37
Setting Parameters Online
Right-click on the row of the parameter you wish to change. A pop-
up window appears (Figure 15) displaying the current value of the
parameter.
Figure 15: Parameter Setting Window
Use the buttons below each digit to change the value of the
parameter. Note that the changed value is sent on-line to the FSP
Amplifier. Some values take effect immediately; others are sent to
the drive but take effect only after the power is cycled. The Need
Reset indicator appears in the status line when this action is
necessary.
4.3.3. Setting Parameters Offline
Double-click on the value field of the desired parameter, and enter
the desired value. The new value is not sent to the drive
automatically (an asterisk appears in the Parameter status
indication column). Use the Download function to send the
changed values to the drive.
4.4. Programming the FSP Amplifier
FSP Amplifier has built-in programming capabilities. You can write a
program that will be executed by the FSP Amplifier without the
need for an external positioning controller.