Pn2C8

Auto tuning – Time between
movements

ms 200-2000

400 5.9.5

Pn2C9

Auto tuning – Speed of
movement

% of

maximum

speed

0-100 50 5.9.5

Pn2CA

Auto tuning – Acceleration time

ms

1-1000

50

5.9.5

Pn2CB

Auto tuning – Plateau time of
movement

ms 0-1000 50 5.9.5

Pn2CC*

Auto start user program

0-99

0

5.10

Pn2D0 Reserved

Pn2D1*

Expand input signal selection 2

0078

5.9.4

Pn2D2*

Expand output signal selection 1

0000

5.9.4

Pn2F0*

Reserved —

Serial communication command

Pn2F1*

Reserved —

Pn300

Speed Reference Input Gain

0.01 V /

rated

speed

150 to

3000

600 5.2.1

Pn301

Speed 1 (rotary motor)

rpm

0-10000

100

5.2.6

Pn302 Speed

2

rpm 0-10000

200 5.2.6

Pn303 Speed

3

rpm 0-10000

300 5.2.6

Pn304 Jog

Speed

rpm 0-10000

500 5.3.2

Pn305

Soft Start Acceleration Time

ms

0-10000

0

6.2.2

Pn306

Soft Start Deceleration Time

ms

0-10000

0

6.2.2

Pn307

Speed Reference Filter Time
Constant

0.01 ms

0-65535

40

Speed Parameters

Pn308

Speed Feedback Filter Time
Constant

0.01 ms

0-65535

0

Pn380

Speed1

mm / s

0-5000

10

Pn381

Speed2

mm / s

0-5000

20

Pn382

Speed3

mm / s

0-5000

30

Linear Motor

Speed

Parameters

Pn383

Jog Speed

mm / s

0-5000

50

Pn400

Torque Reference Input Gain

0.1 V / rated

torque

10-100 30 5.2.7

Pn401

Torque Reference Filter Time
Constant

0.01 ms

0-65535

100

6.2.2

Pn402

Forward Torque Limit

%

0-800

800

5.1.3

Pn403

Reverse Torque Limit

%

0-800

800

5.1.3

Pn404

Forward External Torque Limit

%

0-800

100

5.1.3

Pn405

Reverse External Torque Limit

%

0-800

100

5.1.3

T

orque Parameters

Pn406

Emergency Stop Torque %

0-800

800

5.1.2

Pn407

Speed Limit during Torque
Control

rpm 0-10000

10000 5.2.7

Pn408

Torque Function Switches

0000

6.2.9

Pn409

Notch Filter Frequency Hz

50-2000

2000

6.2.9

T

orque

Parameters

Pn40A

Notch Filter width Hz

70-1000

70

6.2.9

Pn480

Speed limit during torque control

mm / s

0-5000

5000

Pn483

Forward force limit

% of rated

force

0-800 10

Linear Motor

T

orque

Parameters

Pn484

Reverse force limit

% of rated

force

0-800 10

*