Home_sw_c – Yaskawa FSP Amplifier FlexWorks User Manual
Page 137

Command Reference
137
HOME_SW_C
G
ROUP
Home
S
YNTAX
HOME_SW_C
O
P
. C
ODE
130
M
ODES
Program, Sequential
D
ESCRIPTION
Finds the encoder C-pulse only after the home switch is
found. The motor moves at
and then changes direction and moves at
towards the C-pulse. Only then does the encoder counter
zero and the motor decelerate to stop. The motor stops
after the C-pulse. Use the GO or GO_D command to set
the motor at the zero position.
the movement is in opposite directions.
Note: When working with a linear motor and a Yaskawa
serial converter for the encoder, the maximum speed at
which the motor can move to the C-pulse is 5000 linear
scale pitch per second. For example, when the encoder
scale pitch is 20
μm, the maximum speed at which the
motor will move while executing a HOME_C command
will be 100mm/s.
speed1
The speed and direction of searching
for the home switch. Must have an
opposite sign to that of
[speed user units]
Serial
4 V
S
YNTAX
A
RGUMENTS
speed2
The speed and direction of searching
for the C-pulse. Must have an
opposite sign to that of
[speed user units]
Serial
4 V
S
EE
A
LSO
HOME_C, HOME_SW, HARD_HOME
R
ELATED
P
ARAMETERS
Pn2C7.0 – Sets home switch input attribution.