Error Messages

222

C

ODE

M

ESSAGE

D

ESCRIPTION

97

AF1: Power line open phase

98

A.A0: I/O board disconnected

99

A.08: This linear motor is not
supported. ((250*Pn199) /

Pn280) should be an integer

100

A.33: Wrong Input Power.

Amplifier is in AC input mode
(Pn001.2=0), but has DC input
or vice versa.

101

A.80: Position error


102


A.B3: Current detection error.
Please check motor power line
wiring.

103

A.C3: Encoder AB-phase
disconnection of encoder signal
line

104

A.C4: Encoder c-phase

disconnection of encoder signal
line

105

A.C5: Linear motor pole sensor
position detection error.

112

A91: Overload (warning)

113

A92: Regenerative overload

(warning)

128

Reference to invalid label or END
command is missing

Program flow has been directed
to a non-existent label.

129

Command not applicable in this
programming mode
(Program/Immediate/Sequential)

Not all commands are applicable
in all programming modes
(Program/Sequential/Immediate).
The specified command is not
applicable in this mode.

130

Cannot perform this motion with
present profile acceleration

The requested motion cannot be
performed. The specified motion

time is too short for the specified
acceleration.

131

Cannot perform this motion with
present profile speed

The required speed for this
motion is greater than the max.
motor speed. Set a lower motion