Yaskawa FSP Amplifier FlexWorks User Manual
Page 222

Error Messages
222
C
ODE
M
ESSAGE
D
ESCRIPTION
97
AF1: Power line open phase
98
A.A0: I/O board disconnected
99
A.08: This linear motor is not
supported. ((250*Pn199) /
Pn280) should be an integer
100
A.33: Wrong Input Power.
Amplifier is in AC input mode
(Pn001.2=0), but has DC input
or vice versa.
101
A.80: Position error
102
A.B3: Current detection error.
Please check motor power line
wiring.
103
A.C3: Encoder AB-phase
disconnection of encoder signal
line
104
A.C4: Encoder c-phase
disconnection of encoder signal
line
105
A.C5: Linear motor pole sensor
position detection error.
112
A91: Overload (warning)
113
A92: Regenerative overload
(warning)
128
Reference to invalid label or END
command is missing
Program flow has been directed
to a non-existent label.
129
Command not applicable in this
programming mode
(Program/Immediate/Sequential)
Not all commands are applicable
in all programming modes
(Program/Sequential/Immediate).
The specified command is not
applicable in this mode.
130
Cannot perform this motion with
present profile acceleration
The requested motion cannot be
performed. The specified motion
time is too short for the specified
acceleration.
131
Cannot perform this motion with
present profile speed
The required speed for this
motion is greater than the max.
motor speed. Set a lower motion