Command Reference

145

S

YNTAX

A

RGUMENTS

(C

ONT

.)

Value

The value against which the
specified variable value is
compared, for an interrupt to be
triggered.

Serial 4 V

E

XAMPLE

SET_VAR Interrupt_mask 1
MOVE_D 655360 –1
SET_OUTPUT 1 OFF
END
INT Target_velocity >= 400
SET_OUTPUT 1 ON
INT_RETURN –1

E

XAMPLE

E

XPLANATION

The interrupt mask is set so that the program will
only respond to interrupt 0. A motor movement to
position 655360 is started. When, during the motion,
the value of the variable Target_velocity reaches or

exceeds 400, Output 1 will be set ON. The program
will then continue. Once the motor motion has
finished, Output 1 will be set OFF.

S

EE

A

LSO

EXT_INT, INT_RETURN
Variables: Interrupt_mask, Interrupt_request,
Interrupt_pending