beautypg.com

Modifying a profile using variables, Profile, Scaling – Yaskawa FSP Amplifier FlexWorks User Manual

Page 75

background image

Operating the FSP Amplifier Using FlexWorks

75

4.9.14. Modifying a Profile using Variables

The FSP Amplifier includes functionality that allows you to stretch
and shift a profile without having to redefine each segment. Simply
by adjusting the values of variables, you can:

♦ Stretch the profile horizontally by adjusting the Master scale.
♦ Stretch the profile vertically by adjusting the Slave scale.
♦ Shift the profile horizontally.
♦ Offset the profile vertically.

4.9.14.1. Profile

Scaling

The Master scale can be adjusted by multiplying it by a fraction
A/B. If A/B is larger than one, the profile will be stretched. If A/B is

less than one, the profile will be contracted.

♦ A, the numerator, is defined by the variable

ECAM_Master_scale_num.

♦ B, the denominator, is defined by the variable

ECAM_Master_scale_den.

For example, if a scaling factor of 2/3 was applied to the profile
shown below, the Master axis would be contracted by a third.

Figure 45: Sample Profile Before Adjustment

Figure 46: Sample Profile After Master Axis Scaling.