beautypg.com

Home commands hard_home, Home commands, Hard_home – Yaskawa FSP Amplifier FlexWorks User Manual

Page 134

background image

Command Reference

134

HOME Commands

♦ The home switch is a digital input that defines the start point to

search for the C-pulse. Do not define the over travel switch as
the home switch.

♦ The accuracy of Home position in A quad B encoder by C-pulse

is +/- 1 count if the motor searches in the same direction. If the
motor searches in both directions the accuracy is the C-pulse

width +/- 1 count.

HARD_HOME

G

ROUP

Home

S

YNTAX

HARD_HOME

O

P

. C

ODE

131

M

ODES

Program, Sequential

D

ESCRIPTION

Sets the home position using the machine hard stop. The

motor moves at profile acceleration and until
the is reached for 2 seconds and the position

does not change during that time.
If the torque exceeds the torque limit parameters (Pn402
Pn403), the alarm is output: “Torque exceeded Torque

Limits” (err: 33).
The Home Position is defined as the actual position when
the torque reaches the defined for 2 seconds.
The torque will not exceed the defined during

this procedure.
It is recommended to first set a low value. If

the machine hard stop is not found, gradually increase
the value.

This manual is related to the following products: