Maintenance menu, Maintenance, Menu – Yaskawa FSP Amplifier FlexWorks User Manual
Page 22

The Main Screen Interface
22
3.3.2. Maintenance Menu
The Maintenance Menu options allow you to automatically or
manually tune the control loops, to open/close a log file, and to
send a command to the FlexWorks device.
Table 7: Maintenance Menu Options
O
PTION
I
CON
D
ESCRIPTION
Reset
Drive
Cycles the main circuit and control power supply.
This is necessary after certain parameters are
edited, to enable the new settings. The Need
Reset indicator appears in the status line when
this action is necessary.
Reset to
Default
Parameters
Discards user modifications to the parameters
and reverts to the factory default parameters.
Note that some parameters are updated at
power-up only and you must therefore restart
the FSP Amplifier after using this option.
Open Log
File
Starts a new log file and inserts all the
commands sent via communication into the log
file. The log file is used mainly for debugging
purposes.
When this option is selected, the Open Log File
dialog box is displayed.
Figure 6: Open Log File Dialog Box
Select a directory and select the name of an
existing file, or type in a name to create a new
log file. When FlexWorks is in Online mode, all
the commands sent via communication to the
FSP Amplifier are stored in the selected log file.
To close the log file, select the Close Log File
option.