Command Reference

138

IF

G

ROUP

Program Flow Control

S

YNTAX

IF

O

P

. C

ODE

105

M

ODES

Program

D

ESCRIPTION

Defines the different types of conditions/terms that

control the flow of the program. If the IF condition is
true, the action specified by is performed.

Otherwise, the next program line is performed.

variable System variable (see Chapter 9, List of

System Variables).

Serial

1 U

condition Select from:

Condition Code

== 0

> 1

< 2

>= 3

<= 4

!= 5

Serial

1 U

S

YNTAX

A

RGUMENTS

















value

Set a value (or system variable ID
number) with the same units as
.