beautypg.com

Delta Electronics DELTA DUP-B User Manual

Page 42

background image

Chapter 3 Creating and Editing Screens

Example 2:

In Table 3-3-5, the size L is set to 3 and the number N is set to 2 with the recipe data. Thus
the layout of the recipe data will be shown as Table 3-3-6, i.e. RCP0~RCP8 are occupied.
When RCPNO is set to 2 and the recipe buffer area will show the 2

nd

number of recipe data.



Table 3-3-5 Recipe Table Table 3-3-6 Layout of Recipe Registers

32-bit Recipe Register

The size of this register is 32bit (2 Words or Double Word, DW). If the data storage area is an
external memory, i.e. a USB disk or SM card is connected, the data space of 32-bit recipe
register is 50MB words. If the data storage area is an internal memory, the data space of
32-bit recipe register depends on the specification of HMI flash memory. The user can refer
to the specifications shown on DOP-B series catalogue. Please note that not only recipe data,
there are also other screen data stored in flash memory. It indicates the total memory size of
the recipe data space must be less than the space of the flash memory. For more details,
please refer to HMI Memory dialog by clicking View > Memory List (Fig. 3-3-4).

RCP0

12

RCP1

33

RCP2

76

RCP3

36

RCP4

42

RCP5

1

RCP6

12

RCP7

33

RCP8

76

RCPNO = 2

Recipe Buffer

Area

2nd Number of

Recipe Data

Fig. 3-3-4 HMI Memory

Revision May, 2010

3-21