Replacing the Battery
ATCA-7480 Installation and Use (6806800T17A)
324
The battery provides data retention of seven years summing up all periods of actual data use.
Artesyn Embedded Technologies therefore assumes that there is usually no need to replace the
battery except, for example, in case of long-term spare part handling.
Board/System Damage
Incorrect replacement of lithium batteries can result in a hazardous explosion.
Therefore, replace the battery as described in this chapter.
Data Loss
If the battery does not provide enough power anymore, the RTC is initialized and the data in
the NVRAM is lost.
Therefore, replace the battery before seven years of actual battery use have elapsed.
Data Loss
Replacing the battery always results in data loss of the devices which use the battery as
power backup.
Therefore, back up affected data before replacing the battery.
Data Loss
If installing another battery type other than what is mounted at board delivery may cause
data loss. This is because other battery types may be specified for other environments or
may have a shorter lifespan.