IPMI Feature Set
ATCA-7480 Installation and Use (6806800T17A)
300
32
Reset Source
OEM
0xDA
Sensor-specific
discrete
0x6F
0x0
0x2
[7] = IPMC Payload
Reset
[6] = PCH Platform
Reset
[5] = Reserved
[4] = Push Button
Reset RTM
[3] = Reserved
[2] = Push Button
Reset
[1] = XDP Reset
[0] = Power GOOD
Reset
[1] IPMC
Watchdog
Pre-
Timeout
[0] IPMC
Watchdog
Reset
0x0: Payload Reset
detected.
Cause delivered in
Event Byte
2/3
Asrt
Auto
33
ACPI State
System ACPI
Power State
0x22
Sensor-specific
discrete
0x6F
0x0
0x3
0x5
0xFF
0xFF
0x0: S0
0x3: S3
0x5: S5
Asrt
Auto
34
CPU Status
Processor
0x07
Sensor-specific
discrete
0x6F
0x0
0x1
0xFF
0xFF
0x0: IERR
0x1: Thermal Trip
Asrt
Auto
35
ME Pwr Fail
OEM
0xE0
Sensor-specific
discrete
0x6F
0x0
0x1
0x2
0x7
0xFF
0xFF
0x0: Me Fail State
0x1: Me Fail State
0x2: Me Fail State
Asrt
Auto
36
PYLD Pwr
Fail S
OEM
0xE1
Sensor-specific
discrete
0x6F
0x0
0x1
0x2
0x7
0xFF
0xFF
0x0: Pyld Fail State
0x1: Pyld Fail State
0x2: Pyld Fail State
Asrt
Auto
Table 9-2 ATCA-7480 Specific Sensors (continued)
Sensor
Number
Sensor
Name
Sensor Type
Event/Reading
Type
Event Data
Byte 1
Event Data
Byte 2
Event Data
Byte 3
Event
Threshold/
Description
Assertion
Deassertion
Rearm