27 telecom clock supervision registers, Table 5-90, Supervised telecom clocks reference list – Artesyn ATCA-7480 Installation and Use (February 2015) User Manual
Page 165: Table 5-91, Telecom clock monitor control register, Table, Maps and registers

Maps and Registers
ATCA-7480 Installation and Use (6806800T17A)
165
5.1.27 Telecom Clock Supervision Registers
All incoming telecom clocks can be monitored and measured in the range from 1 Hz to 166
MHz. Up to 4 different clock inputs may be monitored. See table below.
Table 5-90 Supervised Telecom Clocks Reference List
Number
Name
Description
0
SYSCLK_IN_CLK1A
CLK1A from backplane
1
SYSCLK_IN_CLK1B
CLK1B from backplane
2
SYSCLK_IN_CLK2A
CLK2A from backplane
3
SYSCLK_IN_CLK2B
CLK2B from backplane
Table 5-91 Telecom Clock Monitor Control Register
Address: 0x60
Bit
Description
Default
Access
3:0
Enable supervised
Telecom Clock 0 to 3
Set corresponding bit
enable monitoring.
0
LPC: r/w
7:4
Reserved
0
r
This manual is related to the following products: