5.1.27 Telecom Clock Supervision Registers

All incoming telecom clocks can be monitored and measured in the range from 1 Hz to 166
MHz. Up to 4 different clock inputs may be monitored. See table below.

Table 5-90 Supervised Telecom Clocks Reference List

Number

Name

Description

0

SYSCLK_IN_CLK1A

CLK1A from backplane

1

SYSCLK_IN_CLK1B

CLK1B from backplane

2

SYSCLK_IN_CLK2A

CLK2A from backplane

3

SYSCLK_IN_CLK2B

CLK2B from backplane

Table 5-91 Telecom Clock Monitor Control Register

Address: 0x60

Bit

Description

Default

Access

3:0

Enable supervised
Telecom Clock 0 to 3
Set corresponding bit
enable monitoring.

0

LPC: r/w

7:4

Reserved

0

r