3 telecom interrupt control register, 4 rtm interrupt status register, 5 external interrupt status register – Artesyn ATCA-7480 Installation and Use (February 2015) User Manual
Page 152: Table 5-70, Telecom interrupt control register, Table 5-71, External interrupt status register, Maps and registers

Maps and Registers
ATCA-7480 Installation and Use (6806800T17A)
152
5.1.16.3 Telecom Interrupt Control Register
Each of the Telecom interrupt source can be enabled.
5.1.16.4 RTM Interrupt Status Register
The RTM Interrupt Status Register will be located in the RTM SPI address space. The host can
access the RTM register using the RTM SPI Master Interface.
5.1.16.5 External Interrupt Status Register
Table 5-70 Telecom Interrupt Control Register
Address Offset: 0x23
Bit
Description
Default
Access
3: 0
Telecom CLK_MONITOR_FINISHED interrupt enable:
Enable/Disable interrupt for the corresponding Clock source:
0: interrupt is disabled
1: Interrupt is enabled
0
LPC: r/w
7:4
Telecom CLK_MONITOR_OUT_OF_RANGE interrupt:
Enable/Disable interrupt for the corresponding Clock source:
0: interrupt is disabled
1: Interrupt is enabled
0
LPC: r/w
Table 5-71 External Interrupt Status Register
Address Offset: 0x24
Bit
Signal/Group
Description
Default
Access
0
RTM_SPI_MISO
RTM interrupt sources
0: RTM_SPI_MISO is high. No RTM
interrupt.
1: RTM_SPI_MISO is low. One or more
RTM interrupt sources are active.
When RTM SPI Master face is active
the current level is latched.
Ext.
LPC: r