Page 305: Table 9-4, Status sensor's sensor reading, Ipmi feature set

background image

IPMI Feature Set

ATCA-7480 Installation and Use (6806800T17A)

305

The boot bank information received from this sensor may differ from the boot bank selection
performed, in case the boot bank selection has changed after the payload has booted. For
details, see

BIOS Boot Bank Selection

on page 315

.

9.3.3

IPMC POST Results Sensor

The POST results sensor is of type 0x28 (Management subsystem health). It returns
information about whether the power-on self-test (POST) of the IPMI firmware passes or not.
For more details about the POST, see

POST

on page 308

.

9.3.4

Power Good Sensor

The Payload Power sensor is of type 0x08 (Power Supply), which reports the state of the
payload power. As the Digital Power Monitor can disable payload power by its own due to a
faulty DC-DC converter, the IPMC monitors the health and reports an event in the case where
the Digital Power Monitor disables power-on by its own. As a result of this, the IPMC will pro-
actively transition the IPMC from M4 to M6 (to M1) with a cause code of 0x09 (Unexpected
Deactivation). This automatic shutdown is meant to keep the IPMC's state in-line with the
payload state.

9.3.5

Power Interface Sensors

An Ericsson Power input module (PIM4328) is used for the 48v to 12v conversion monitoring.
The PIM includes sensors, which monitor the shelf's 48v input feeds current, hold-up capacitor
voltage, on-board temperature, and internal status. The status sensor reading can be decoded
as shown in

Table 9-4

.

Table 9-4 Status Sensor's Sensor Reading

Bit 7

Reserved

0

Bit 6

-48v Output Under
Voltage Alarm

0: Output Voltage is below threshold
1: Output Voltage is above threshold

Bit 5

Hot-swap Switch State

0: Hot-swap switch is off
1: Hot-swap switch is on

Bit 4

Holdup Switch State

0: Holdup Cap is not connected to -48V Out
1: Holdup Cap is connected to -48V Out