beautypg.com

9 set handle switch command, 10 get payload communication time-out command, Table 8-37 – Artesyn ATCA-7480 Installation and Use (February 2015) User Manual

Page 269: Set handle switch command description, Table 8-38, Ime-out, Supported ipmi commands

background image

Supported IPMI Commands

ATCA-7480 Installation and Use (6806800T17A)

269

8.4.9

Set Handle Switch Command

The Set Handle Switch command sets the state of the hot-swap handle switch in manual
standalone mode (for a description refer to

Table 8-28

).

8.4.10 Get Payload Communication Time-Out Command

The Get Payload Communication Time-Out command reads the payload communication
time-out value.

Table 8-37 Set Handle Switch Command Description

Type Byte

Data

Field

Request Data

1:3

PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00

4

Handle Switch Status
0x00: The handle switch is open.
0x01: The handle switch is closed.
0x02: The handle switch state is read from hardware.

Response Data

1

Completion Code

2:4

PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00

Table 8-38 Get Payload Communication Time-Out Command Description

Type Byte

Data

Field

Request Data

1:3

PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00

Response Data

1

Completion Code

2:4

PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00