9 set handle switch command, 10 get payload communication time-out command, Table 8-37 – Artesyn ATCA-7480 Installation and Use (February 2015) User Manual
Page 269: Set handle switch command description, Table 8-38, Ime-out, Supported ipmi commands
Supported IPMI Commands
ATCA-7480 Installation and Use (6806800T17A)
269
8.4.9
Set Handle Switch Command
The Set Handle Switch command sets the state of the hot-swap handle switch in manual
standalone mode (for a description refer to
).
8.4.10 Get Payload Communication Time-Out Command
The Get Payload Communication Time-Out command reads the payload communication
time-out value.
Table 8-37 Set Handle Switch Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4
Handle Switch Status
0x00: The handle switch is open.
0x01: The handle switch is closed.
0x02: The handle switch state is read from hardware.
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
Table 8-38 Get Payload Communication Time-Out Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00