Maps and registers – Artesyn ATCA-7480 Installation and Use (February 2015) User Manual
Page 137
Maps and Registers
ATCA-7480 Installation and Use (6806800T17A)
137
2
5V power good failure (signal PWRGD_VP5):
0: No 5V power issue.
1: 5V power failure.
PWR_GOOD:0
IPMC: r
3
1.0V power good failure (signal PWRGD_V1P0):
0: No 1.0V power issue.
1: 1.0V power failure.
PWR_GOOD:0
IPMC: r
4
0.75V power good failure (signal PWRGD_V0P75):
0: No 0.75V power issue.
1: 0.75V power failure.
PWR_GOOD:0
IPMC: r
5
3.3V and 1.05V power good failure (signal
PWRGD_V3P3_V1P05):
0: No 3.3V and 1.05 power issue.
1: 3.3V and 1.05 power failure.
PWR_GOOD:0
IPMC: r
6
1.8V power good failure (signal PWRGD_V1P8):
0: No 1.8V power issue.
1: 1.8V power failure.
PWR_GOOD:0
IPMC: r
7
1.5V power good failure (signal PWRGD_V1P5):
0: No 1.5V power issue.
1: 1.5V power failure.
PWR_GOOD:0
IPMC: r
Table 5-50 Payload Power Failure Cause Register 2 (continued)
Address Offset: 0x0C
Bit
Description
Default
Access