0x5

S3

One or more of these voltages have failed:
12V, 5V aux, VPP or VDD

0x7

TRACK_MASTE
R_ON

Timeout (debug disabled) after 280ms. Tracked voltages are
not good.
Other cause: 12V or 5V aux power failure

0x8

VCCIN_ENABL
E

Timeout (debug disabled) after 280ms. VCCIN voltages are
not good.
Other cause: One or more voltages have failed, which have
been already enabled and sampled good.

0x9

VCCIO_VPP_E
NABLE

Timeout (debug disabled) after 280ms. VCCIO and VPP
voltages are not good.
Other cause: One or more voltages have failed, which have
been already enabled and sampled good.

0xA

VDDQ_ENABL
E

Timeout (debug disabled) after 280ms. VDD voltages are not
good.
Other cause: One or more voltages have failed, which have
been already enabled and sampled good.

0xB

VP12_ON

Timeout (debug disabled) after 280ms. 12V or 5V aux
voltages are not good.

0xC

VTT_ENABLE

Timeout (debug disabled) after 280ms. VTT voltages are not
good.
Other cause: One or more voltages have failed, which have
been already enabled and sampled good.

0xD

WAIT_100MS

One or more voltages have failed, which have been already
enabled and sampled good.

0xE

WAKE_UP

Timeout. Board does not wake up within 5s

Other

-

These values will never occur.