Installation – Artesyn ATCA-7480 Installation and Use (February 2015) User Manual
Page 26

ATCA-7480 Installation and Use (6806800T17A)
Safety Notes
26
This is a Class A product based on the standard of the Voluntary Control Council for
Interference by Information Technology Interference (VCCI). If this equipment is used in a
domestic environment, radio disturbance may arise. When such trouble occurs, the user may
be required to take corrective actions.
The blade generates and uses radio frequency energy and, if not installed properly and used in
accordance with this guide, may cause harmful interference to radio communications.
Operating the system in a residential area is likely to cause harmful interference, in which case
the user will be required to correct the interference at his own expense.
The COM, ETH1, ETH2, USB1 and USB2 interfaces are considered as debug/maintenance
ports. During normal operation no cables must be connected to these ports. Cables attached
to these ports during maintenance must not exceed a length of 3m.
Installation
Damage of Circuits
Electrostatic discharge and incorrect blade installation and removal can damage circuits or
shorten their life.
Before touching the blade or electronic components, make sure that you are working in an
ESD-safe environment.
Data
Loss
Removing the blade with the blue LED still blinking causes data loss.
Wait until the blue LED is permanently illuminated, before removing the blade.
Restricted access area - This board is only to be installed in a restricted access area.
Damage of Blade and Additional Devices and Modules
Incorrect installation of additional devices or modules may damage the blade or the additional
devices or modules.
Before installing or removing an additional device or module, read the respective
documentation