Table 5-92, Telecom clock monitor status register, Table 5-93 – Artesyn ATCA-7480 Installation and Use (February 2015) User Manual
Page 166: Telecom clock monitor out of range register, Table, Maps and registers
Maps and Registers
ATCA-7480 Installation and Use (6806800T17A)
166
When at least one bit of the
is set, the corresponding status bit
CLK_MONITOR_FINISHED of the
is also set.
When at least one bit of the
is set, the corresponding status bit
CLK_MONITOR_OUT_OF_RANGE of
is also set.
Table 5-92 Telecom Clock Monitor Status Register
Address: 0x61
Bit
Description
Default
Access
3:0
Result available for supervised Telecom Clock 0 to 3.
Corresponding bit is set when measurement has
finished.
Clearing bit triggers new measurement.
0
LPC: r/w1c
7:4
Reserved
0
r
Table 5-93 Telecom Clock Monitor Out of Range Register
Address: 0x62
Bit
Description
Default
Access
3:0
Frequency of supervised Telecom Clock 0 to 3 is out of range.
Gate Mode:
Corresponding bit is set when the number of positive Clock
edges within the selected time base is:
< Lower limit or
> Upper limit
Period Mode:
Corresponding bit is set when the Clock 0 Period within the
selected time base is:
< Lower limit or
> Upper limit
Clearing bit triggers new sequence of measurements.
0
LPC: r/w1c
7:4
Reserved
0
r