Table 5-92, Telecom clock monitor status register, Table 5-93 – Artesyn ATCA-7480 Installation and Use (February 2015) User Manual

Page 166: Telecom clock monitor out of range register, Table, Maps and registers

background image

Maps and Registers

ATCA-7480 Installation and Use (6806800T17A)

166

When at least one bit of the

Table 5-91

is set, the corresponding status bit

CLK_MONITOR_FINISHED of the

Table 5-69

is also set.

When at least one bit of the

Table 5-93

is set, the corresponding status bit

CLK_MONITOR_OUT_OF_RANGE of

Table 5-69

is also set.

Table 5-92 Telecom Clock Monitor Status Register

Address: 0x61

Bit

Description

Default

Access

3:0

Result available for supervised Telecom Clock 0 to 3.
Corresponding bit is set when measurement has
finished.
Clearing bit triggers new measurement.

0

LPC: r/w1c

7:4

Reserved

0

r

Table 5-93 Telecom Clock Monitor Out of Range Register

Address: 0x62

Bit

Description

Default

Access

3:0

Frequency of supervised Telecom Clock 0 to 3 is out of range.
Gate Mode:
Corresponding bit is set when the number of positive Clock
edges within the selected time base is:
< Lower limit or
> Upper limit
Period Mode:
Corresponding bit is set when the Clock 0 Period within the
selected time base is:
< Lower limit or
> Upper limit
Clearing bit triggers new sequence of measurements.

0

LPC: r/w1c

7:4

Reserved

0

r