2 get feature configuration, Table 8-25, Feature selector assignments – Artesyn ATCA-7480 Installation and Use (February 2015) User Manual
Page 257: Table 8-26, Get feature configuration command, Supported ipmi commands
Supported IPMI Commands
ATCA-7480 Installation and Use (6806800T17A)
257
The following table provides the feature set supported with ATCA-7480:
8.3.2.2
Get Feature Configuration
This command can be used to get the state of feature configuration during IPMC runtime.
Table 8-25 Feature Selector Assignments
Feature Selector
Description
(3) 03h
Handle Debounce
(224) E0h
FAILSAFE Function Enable/Disable. For details, see
(225)E1h
FAIL PROTECT Function Enable/Disable. For details, see
Table 8-26 Get Feature Configuration Command
Byte Data
Field
Request Data
1
LSB of Artesyn IANA Enterprise Number. A value of CDh shall be
used.
2
2nd byte of Artesyn IANA Enterprise Number. A value of 65h
shall be used.
3
MSB of Artesyn IANA Enterprise Number. A value of 00h shall
be used.
4
Feature Selector, for details see table 3