2 payload power failure registers, Table 5-46, Me power failure cause register – Artesyn ATCA-7480 Installation and Use (February 2015) User Manual

Page 133: Maps and registers

background image

Maps and Registers

ATCA-7480 Installation and Use (6806800T17A)

133

The table below shows the failing cause for the ME power failure.

5.1.11.2 Payload Power Failure Registers

When a payload power failure occurs, the red power failure LED is switched ON (signal
PWR_FAIL_ is driven low).

3

ME_PWR

Timeout. No ASW power good after 45ms

4

ME_WAIT

ASW power good lost

5

ME_WAIT_OFF

ASW power good lost

Other

-

These values will never occur.

Table 5-46 ME Power Failure Cause Register

Address Offset: 0x09

Bit

Description

Default

Access

0

Active Sleep Well (ASW) power failure:
0: No ASW power failure. ASW power is as expected.
1: ASW power failure. ASW power has different value
as expected.
Note: Only valid when ME Failure (Bit 7) of ME Power
Failure State Register (

Table 5-47

) is set.

PWR_GOOD:0

IPMC: r

7:1

Reserved

0

IPMC: r

Table 5-45 ME Power Failure States (continued)

State
Coding

State
Name

Description