SCC/ESCC

User Manual

UM010903-0515

SCC/ESCC Ancillary Support Circuitry

78

DPLL Digital Phase-Locked Loop

Each channel of the SCC contains a digital phase-locked loop that can be used to recover clock

information from a data stream with NRZI, FM, NRZ, or Manchester encoding. The DPLL is

driven by a clock nominally at 32 (NRZI) or 16 (FM) times the data rate. The DPLL uses this

clock, along with the data stream, to construct a receive clock for the data. This clock can then be

used as the SCC receive clock, the transmit clock, or both.

Figure

displays a block diagram of the digital phase-locked loop. It consists of a 5-bit counter, an

edge detector, and a pair of output decoders. The clock for the DPLL comes from the output of a

two-input multiplexer, and the two outputs go to the transmitter and receive clock multiplexers.

The DPLL is controlled by seven commands encoded in WR14 bits D7, D6 and D5.

Digital Phase-Locked Loop

The clock source for the DPLL is selected issuing one of the two commands in WR14, that is:
WR14 (7-5) = 100 selects the BRG
WR14 (7-5) = 101 selects the /RTxC pin
The first command selects the baud rate generator as the clock source. The other command selects

the /RTxC pin as the clock source, independent of whether the /RTxC pin is a simple input or part

of the crystal oscillator circuit.

Initialization of the DPLL is done at any time during the initialization sequence, but should be

done after the clock modes have been selected in WR11, and before the receiver and transmitter

are enabled. When initializing the DPLL, the clock source should be selected first, followed by the

selection of the operating mode.

To avoid metastable problems in the counter, the clock source selection is made only while DPLL

is disabled, since arbitrarily narrow pulses are generated at the output of the multiplexer when it

changes status.

The DPLL is programmed to operate in one of two modes, as selected by commands in WR14.
WR14 (7-5) = 111 selects NRZI mode