Interrupt Acknowledge Cycle Timing
The primary timing differences between the Z180 and SCC occur in the Interrupt Acknowledge
cycle. The SCC timing parameters that are significant during Interrupt Acknowledge cycles are in
Table on page 231. The Z180 timing parameters are in Table . The reference numbers in Table
and Table refer to Figure on page 230.
10 MHz SCC Timing Parameters for Interrupt Acknowledge Cycle
No
Symbol
Parameter
Min
Max
Units
13
TsIAi(RD)
/INTACK Low to /RD Low
Setup
130
ns
14
ThIA(RD)
/INTACK High to /RD
High Hold
0
ns
15
ThIA(PC)
/INTACK to PCLK High
Hold
30
ns
38
TwRDA
/INTACK Low to /RD Low
Delay (Acknowledge)
125
ns
39
TwRDA
/RD (Acknowledge) Width 125
ns
40
TdRDA(DR) /RD Low (Acknowledge)
to Read Data Valid Delay
120
ns
41
TsIEI(RDA) IEI to /RD Low
(Acknowledge) Setup
Time
95
ns
42
ThIEI(RDA) IEI to /RD High
(Acknowledge) Hold Time
0
ns
43
TdIEI(IEO)
IEI to IEO Delay
175