5.
Once all scenes have been added, use the up and down arrows located under the menu listing to adjust the
order in which the scenes are presented.
6.
After adjusting information, select Apply.
NOTE:
For information on the Input Sensor tab, see Input Sensor Tab on page 5-85.
ControLinX and Aprilaire
To edit ControLinX settings for Aprilaire, complete the following steps:
1.
Connect the ControLinX with the Aprilaire 8811 Protocol Adapter using the DigiLinX RS232 cable
(included). This cable is used with the cables supplied by Aprilaire and an RS-232 gender changer.
2.
Click on the ControLinX in your project that is connected to the Aprilaire HVAC system.
The Info tab for the ControLinX hosting Aprilaire displays in the right side of the window (see Figure 5-72).
Figure 5-77
ControLinX with Aprilaire Info tab
Table 5-60
Menu Tab
Tab
Selection Description
Menu
List of Rooms
Select the room from the list of rooms for the lighting control
buttons to appear on the menu for that room.
Room Scenes Enabled
Check this box to allow you to edit the available scenes for a
particular room.
Available Scenes
Select the scene and click the right arrow to move the scene
to the room.
The name of the room for which you are enabling scenes.