Clearing Fields/Loads From

Ag Leader Technology

Memory

June 1997

4-31

Introduction

The Yield Monitor allows you to clear fields and loads from the memory on
two levels:

You can clear data that is collected into loads by clearing them

individually.

You can clear all fields and loads in the monitor, leaving only Field

1/Load 1.

Recommendation: Clear all fields in the monitor before beginning a new
harvest season. When you clear all fields, the monitor allows you to save all
the calibration loads and/or keep the field names, but erase all other loads.

You can store up to 976 loads and 255 fields in the monitor, which is
normally more than enough for one year. Press the MEM key until “xxx
LOADS REMAINING” appears on the display to see how many new loads
the monitor has available.

Clearing
Individual Loads

Follow these steps to clear data that has been accumulated in a load:

Step

Action

1

Press the FIELD and LOAD keys and then use the top UP and
DOWN ARROW keys to display the load you want to clear.

2

Press the MEM key until “CLEAR DATA IN THIS LOAD?”
appears on the display.

3

Press the YES Key. The monitor will beep four times quickly and
“ARE YOU REALLY SURE?, YOU WILL LOSE DATA!” will
appear on the display.

4

If you . . .

Then . . .

Want to continue to clear the
data from this Load,

Press the YES key again.

If you have changed your mind
about clearing the load,

Press any other key.