Grain Type
Yield Monitor 2000
Ag Leader Technology
June 1997
4-26
Introduction
You can have only one grain type per field. If you have one field with two
different crops in it (example: 80 acre field with 40 acres of soybeans and 40
acres of corn), you must use two fields
one for each grain type
in the
monitor.
Each grain type has the following settings.
•
Grain calibration numbers (C2-C11, monitor sets these when calibrated)
•
Moisture calibration number
•
Dry % value (for example, 13% for soybeans)
•
Dry lbs/bu
•
Vibration calibration number (C1)
•
Swath setting
•
Stop height number
Dry lbs/bu
You can set the dry lbs/bu of the grain for each grain type except corn (56
lbs/bu), soybeans (60 lbs/bu), and wheat (60 lbs/bu). Follow these steps to
set the dry lbs/bu:
Step
Action
1
Press the GRAIN key until “xx DRY LB/B” appears on the display.
2
Use the bottom-left UP or DOWN ARROW keys to change the
value.
Note: This will change the bushels for all loads set on that grain
type.
Dry % Moisture
Follow these steps to set the dry % value:
Step
Action
1
Press the GRAIN key until “xx.x DRY %” appears on the display.
2
Use the bottom-left UP or DOWN ARROW keys to change the
value.
Note: This will change the bushels for all loads set on that grain
type.