background image

Grain Type

Yield Monitor 2000

Ag Leader Technology

June 1997

4-26

Introduction

You can have only one grain type per field. If you have one field with two
different crops in it (example: 80 acre field with 40 acres of soybeans and 40
acres of corn), you must use two fields

one for each grain type

in the

monitor.

Each grain type has the following settings.

Grain calibration numbers (C2-C11, monitor sets these when calibrated)

Moisture calibration number

Dry % value (for example, 13% for soybeans)

Dry lbs/bu

Vibration calibration number (C1)

Swath setting

Stop height number

Dry lbs/bu

You can set the dry lbs/bu of the grain for each grain type except corn (56
lbs/bu), soybeans (60 lbs/bu), and wheat (60 lbs/bu). Follow these steps to
set the dry lbs/bu:

Step

Action

1

Press the GRAIN key until “xx DRY LB/B” appears on the display.

2

Use the bottom-left UP or DOWN ARROW keys to change the
value.

Note: This will change the bushels for all loads set on that grain
type.

Dry % Moisture

Follow these steps to set the dry % value:

Step

Action

1

Press the GRAIN key until “xx.x DRY %” appears on the display.

2

Use the bottom-left UP or DOWN ARROW keys to change the
value.

Note: This will change the bushels for all loads set on that grain
type.