Yield Monitor 2000

Logging Settings

Ag Leader Technology

June 1997

2-13

Setting Log
Without Grain
Flow

To set the log without grain flow, press the SETUP key until “LOG W/O
GRAIN FLOW =NO or YES “ appears on the display.

If you are operating
the Monitor . . .

Then . . .

In a combine,

Set this to NO, using the top UP or DOWN
ARROW keys.

Note: The yield and GPS information is logged
only when the elevator speed is more than 250
rpm and acres are counting, or the grain flow is
more than 0 BU/HR.

On vehicles other than
combines,

Set this to YES using the top UP or DOWN
ARROW keys.

Note: GPS information is logged only when the
area count light is off (counting acres). This
allows you to perform site verification (refer to
the Options section for more information).

* * *