Yield monitor 2000, Ag leader technology – Ag Leader Yield Monitor 2000 Operators Manual User Manual
Page 103

Yield Monitor 2000
Logging Map Data to a Card
Ag Leader Technology
June 1997
4-37
The number of yield readings taken per foot traveled are also dependent on
your logging interval:
Distance Traveled (ft)
1 sec
2 sec
3 sec
3 mph
4.4
8.8
13.2
5 mph
7.3
14.6
21.9
Setting Log W/O
Follow these steps to finish setting the logging interval:
Grain Flow
Step
Action
1
Press the SETUP key until “LOG W/O GRAIN FLOW=NO or
YES” appears on the display.
2
Use the top-right UP or DOWN ARROW key to set this to:
•
NO if you are using the monitor in a combine
Note: When LOG W/O GRAIN FLOW=NO, the monitor logs to
the card when the elevator speed is more than 250 rpm and you
are either counting acres or have a grain flow of more than 0
bu/hr.
•
YES if you are using the monitor in a vehicle other than the
combine. Refer to the Options section.
Note: When LOG W/O GRAIN FLOW=YES the monitor logs
to the card when the area count light is off.
Inserting Memory
Cards
For maximum data security, memory cards should be inserted and
removed only when the monitor's power is off.
Note: An exception to this is when the monitor asks you to insert a memory
card.
The memory card has slots on its sides with different shapes, which match
the connector inside the monitor. Thus, you cannot install the card
backwards.
Insert the end of the card that has 68 small holes in it into the monitor with
the "front" side of the card (the side with the manufacturer’s name or logo)
toward the right end of the monitor. Be sure to insert the card completely, so
that it makes good contact and remains in place.