Calculating Dry Bushels

Ag Leader Technology

June 1997

7-3

Example:

1
------------- = 1.183 per point (difference between actual and dry%
1-15.5/100 moisture)

Dry bushels calculated using the shrink factor can be found using the
following equation:

Wwg - (S.F. x (Mwg-Mdg)/100 x Wwg) = Dry bushels
Dry lbs/bu

150,000 - (1.183 x (25-15.5)/100 x 150,000) = 2,377 bu

56

* * *