beautypg.com

Yield monitor 2000, Ag leader technology – Ag Leader Yield Monitor 2000 Operators Manual User Manual

Page 15

background image

Yield Monitor 2000

Logging Settings

Ag Leader Technology

June 1997

2-11

Selecting a
Logging Device

The instantaneous yield and GPS data are not recorded in the monitor’s
internal memory, but are logged to a separate device; either a memory card
or an external datalogger, which connects to the nine-pin serial port on the
monitor.

To select a logging device, press the SETUP key until “LOGGING DEVICE
=NONE or ?M CARD or EXT” appears on the display. Use the top UP or
DOWN ARROW keys to select the correct setting from the menu choices:

NONE: Select this setting if you do not have a GPS receiver and

therefore are not logging instantaneous yield and GPS information on
either a memory card or a datalogger.

?M CARD: Select this setting if you have a GPS receiver and will be

logging instantaneous yield and GPS information to a memory card in
the yield monitor. The ? changes to the size of the card that was last
formatted in the monitor.

EXT: Select this setting if you have a GPS receiver and will be logging

instantaneous yield and GPS information to an external datalogger.

Notes:

The monitor will not log to a memory card and datalogger at the same

time.

The LOGGING DEVICE must be set on ?M CARD for the monitor to

receive a GPS signal.

When the monitor is turned on with the logging device set for a card, the

monitor beeps and asks you to “INSTALL CARD OR PRESS NO”
before it advances to the normal operating mode. Press the NO key if
you do not have a card and want to advance to the next operating mode.