Yield monitor 2000, Ag leader technology – Ag Leader Yield Monitor 2000 Operators Manual User Manual
Page 15

Yield Monitor 2000
Logging Settings
Ag Leader Technology
June 1997
2-11
Selecting a
Logging Device
The instantaneous yield and GPS data are not recorded in the monitor’s
internal memory, but are logged to a separate device; either a memory card
or an external datalogger, which connects to the nine-pin serial port on the
monitor.
To select a logging device, press the SETUP key until “LOGGING DEVICE
=NONE or ?M CARD or EXT” appears on the display. Use the top UP or
DOWN ARROW keys to select the correct setting from the menu choices:
•
NONE: Select this setting if you do not have a GPS receiver and
therefore are not logging instantaneous yield and GPS information on
either a memory card or a datalogger.
•
?M CARD: Select this setting if you have a GPS receiver and will be
logging instantaneous yield and GPS information to a memory card in
the yield monitor. The ? changes to the size of the card that was last
formatted in the monitor.
•
EXT: Select this setting if you have a GPS receiver and will be logging
instantaneous yield and GPS information to an external datalogger.
Notes:
•
The monitor will not log to a memory card and datalogger at the same
time.
•
The LOGGING DEVICE must be set on ?M CARD for the monitor to
receive a GPS signal.
•
When the monitor is turned on with the logging device set for a card, the
monitor beeps and asks you to “INSTALL CARD OR PRESS NO”
before it advances to the normal operating mode. Press the NO key if