HP Hitachi Dynamic Link Manager Software User Manual
Page 60
2. HDLM Functions
36
check the IEP item displayed when the
dlnkmgr
command's
view -path
operation
is executed with the
-iem
parameter specified. If 0 or greater is displayed in the
Intermittent Error Path item, then intermittent error monitoring is being performed.
Table 2-7: When Effects of a User Changing the Intermittent Error Information
#1
User operation
Number of errors
and time passed
since error
monitoring
started
Information
about paths not
subject to
automatic
failback
Changing the intermittent
error monitoring settings
Turning
off
Reset
Reset
#1
Changing the conditions for an
intermittent error while intermittent
error monitoring is being performed
Reset
#2
Inherited
Turning intermittent error
monitoring
on
by executing the
set
operation, (but not changing the
conditions) while intermittent error
monitoring is being performed
Changing the intermittent error
monitoring conditions while
intermittent error monitoring is not
being performed
(Not applicable) (Not
counted.)
Inherited
Changing the automatic
failback settings
Turning
off
Reset
Reset
Changing the path status
Taking the path
Offline(C)
Reset
Reset
Placing the path
Online
while
intermittent error monitoring is not
being performed
(Not applicable) (Not
counted.)
Reset
Placing the path
Online
while
intermittent error monitoring is
being performed
Inherited
(Not applicable)
If a path has been
removed from the
paths subject to
automatic
monitoring, that
path is no longer
monitored.
Restarting the HDLM manager
Reset
#3
Inherited
Restarting the host
Reset
Reset