beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 60

background image

2. HDLM Functions

36

check the IEP item displayed when the

dlnkmgr

command's

view -path

operation

is executed with the

-iem

parameter specified. If 0 or greater is displayed in the

Intermittent Error Path item, then intermittent error monitoring is being performed.

Table 2-7: When Effects of a User Changing the Intermittent Error Information

#1

User operation

Number of errors

and time passed

since error
monitoring

started

Information

about paths not

subject to
automatic

failback

Changing the intermittent
error monitoring settings

Turning

off

Reset

Reset

#1

Changing the conditions for an

intermittent error while intermittent

error monitoring is being performed

Reset

#2

Inherited

Turning intermittent error

monitoring

on

by executing the

set

operation, (but not changing the
conditions) while intermittent error

monitoring is being performed

Changing the intermittent error
monitoring conditions while

intermittent error monitoring is not

being performed

(Not applicable) (Not
counted.)

Inherited

Changing the automatic

failback settings

Turning

off

Reset

Reset

Changing the path status

Taking the path

Offline(C)

Reset

Reset

Placing the path

Online

while

intermittent error monitoring is not

being performed

(Not applicable) (Not

counted.)

Reset

Placing the path

Online

while

intermittent error monitoring is

being performed

Inherited

(Not applicable)
If a path has been
removed from the

paths subject to

automatic
monitoring, that

path is no longer

monitored.

Restarting the HDLM manager

Reset

#3

Inherited

Restarting the host

Reset

Reset

This manual is related to the following products: