8. Messages

540

None.

KAPL01079-W

The intermittent error monitoring function cannot be set up
because automatic failback is disabled.

Details

The intermittent error monitoring function cannot be set up because automatic

failbacks are disabled.

Action

Enable automatic failbacks, and then re-execute.

KAPL01080-W

The error monitoring interval and the number of times that the
error is to occur conflict with the automatic failback checking
interval.

Details

An intermittent error cannot be detected by using the values specified for the

following: the checking interval for automatic failbacks, the error-monitoring

interval, and the number of times the error needs to occur.

Action

Set the intermittent error-monitoring interval to a value that is equal to or greater

than (automatic-failback-checking-interval

x

number-of-times-error-is-to-occur-for-intermittent-error-monitoring).

KAPL01081-E

The license key file is invalid. File name =

aa...aa

Details

The format of the license key file is invalid.
aa...aa:

/var/tmp/hdlm_license

Action

Save the correct license key file in the designated, and then re-execute.

/var/tmp/hdlm_license

KAPL01082-E

There is no installable license key in the license key file. File
name =

aa...aa

Details

There is no useable license key for HDLM in the license key file.
aa...aa:

/var/tmp/hdlm_license

This manual is related to the following products: