beautypg.com

2 manual path switching – HP Hitachi Dynamic Link Manager Software User Manual

Page 52

background image

2. HDLM Functions

28

Storage Platform V/VM, Virtual Storage Platform, Hitachi AMS2000 series, or

Hitachi SMS is being used, all the paths are owner paths. As a result, if the path that

was previously used recovers from an error, and then HDLM automatically places the

recovered path online, the path that is currently being used will continue to be used (as

opposed to switching over to the path that was just recovered).

When intermittent errors

#

occur on paths and you are using the automatic failback

function, the path status might frequently alternate between the online and offline

statuses. In such a case, because the performance of I/Os will most likely decrease, if

there are particular paths in which intermittent errors might be occurring, we

recommend that you set up intermittent error monitoring so you can detect these paths,

and then remove them from those subject to automatic failbacks.
You can specify the automatic failback function or intermittent error by the

dlnkmgr

command's

set

operation. For details on the

set

operation, see 6.6 set (Sets Up the

Operating Environment).
#

An intermittent error means an error that occurs irregularly because of some

reason such as a loose cable connection.

2.8.2 Manual Path Switching

You can switch the status of a path by manually placing the path online or offline.

Manually switching a path is useful, for example, when system maintenance needs to

be done.
You can manually place a path online or offline by doing the following:

Execute the

dlnkmgr

command's

online

or

offline

operation.

For details on the

online

operation, see 6.5 online (Places Paths Online). For

details on the

offline

operation, see 6.4 offline (Places Paths Offline).

However, if there is only one online path for a particular LU, that path cannot be

manually switched offline. Also, a path with an error that has not been recovered from

yet cannot be switched online.
HDLM uses the same algorithms to select the path that will be used next, regardless of

whether automatic or manual path switching is used.
When using the Thunder 9500V series, or Hitachi AMS/WMS series, HDLM will

select the next path to be used first from among the online owner paths, and then from

the online non-owner paths. When the Lightning 9900 series, Lightning 9900V series,

Hitachi USP, Universal Storage Platform V/VM, Virtual Storage Platform, Hitachi

AMS2000 series, or Hitachi SMS is being used, all the paths that access the same LU

as the path that is currently being used are candidates for the switching destination

path.

This manual is related to the following products: