beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 157

background image

3. Creating an HDLM Environment

133

3.5 Notes on Creating an HDLM Environment

This section provides notes on creating an HDLM environment.
For notes on operating HDLM, see 4.1 Notes on Using HDLM.

3.5.1 Notes on Hardware Settings

„

The types of HBA that are installed on one host can be mixed. However, the

HBAs connected to an HDLM-managed device must all be of the same type. Also

make sure that the HBA driver versions are the same. If the types or versions of

HBAs connected to the devices for the HDLM-managed SCSI disks vary, you

cannot switch the path when an error occurs.

„

You must not change the vendor ID and product ID of the storage system.
If you change these IDs, HDLM cannot recognize the storage system.

„

Make sure that you start the storage system before starting the host.

„

When a device is added to a PCI bus, and the IRQ is shared with the HBA and

other devices, a problem might occur. When adding a device, make sure that the

IRQ is not shared with other devices.

„

Note the following in an environment where a host is connected to a storage

system by using a fibre channel switch.

If the host starts while the path between the fibre channel switch and the

storage system is disconnected, the target ID of the path might be changed

after the host restarts. At that time, the disconnected path might not be

recoverable while the host is running. Also, when you execute the HDLM

command to display the path status, the target ID of the path before the

change might be displayed or the disconnected path might not be displayed.
In either case, change the disconnected path so that the configuration is the

same as that used when that path operated normally. Physically restore the

disconnected path in the same configuration where it used to operate

normally. If the HDLM device name has been changed, reconfigure the

higher-level program.

If the zone setting for the fibre channel switch has changed, the target ID of

the path might have also changed. When you execute the HDLM command

to display the path status, the target ID of the path before the change might

be displayed. In addition, the HDLM device name might be changed after the

host is restarted. Check the HDLM device name after the host is restarted. If

the HDLM device name has been changed, reconfigure the higher-level

program.

This manual is related to the following products: