6. Command Reference

405

HBA port that has the specified host port number and bus number.
Specify the host port number and bus number of the target HBA port: the numbers

are found in the PathName field displayed using the

view

operation. Enter a

period between these two parameter values. For details about the

view

operation,

see 6.7 view (Displays Information).
Example

The following example shows how to place offline all paths connected to the

HBA port whose host port number is

0010

and bus number is

0000

:

When the confirmation message is displayed, the user enters

y

to continue,

or

n

to cancel the operation.

# /opt/DynamicLinkManager/bin/dlnkmgr offline -hba
0010.0000
KAPL01055-I All the paths which pass the specified HBA
will be changed to the Offline(C) status. Is this OK? [y/
n]:y
KAPL01056-I If you are sure that there would be no problem
when all the paths which pass the specified HBA are placed
in the Offline(C) status, enter y. Otherwise, enter n.
[y/n]:
KAPL01061-I 3 path(s) were successfully placed
Offline(C); 0 path(s) were not. Operation name = offline
#

-cha -pathid

AutoPATH_ID

Use this parameter to place offline, at one time, all the paths that pass through a

specific CHA port. The command will place offline all the paths that pass through

the CHA port to which the path with the specified AutoPATH_ID is connected.
Specify the current AutoPATH_ID of the target path, which is displayed by using
the

view

operation. For details about the

view

operation, see 6.7 view (Displays

Information). Leading zeros can be omitted (

000001

and

1

indicate the same

AutoPATH_ID); however, when the target AutoPATH_ID is

000000

, enter

000000

or

0

for the parameter value.

AutoPATH_IDs are re-assigned every time the host is restarted. When you want

to add a new LU without restarting the host, AutoPATH_IDs are re-assigned to

each path of the LU when you execute the

dlmcfgmgr

utility for managing the

HDLM configuration. Always make sure that you use the

view

operation to find

the current AutoPATH_ID of the target path, before executing the

offline

operation.
Example

The following example shows how to place offline all the paths connected to

the CHA port

0A

. In this example, a path whose AutoPATH_ID is

000001

is