beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 472

background image

6. Command Reference

448

IO-Count

#

-

Total I/O count for the path, indicated by a decimal number. The maximum value
that can be displayed is 2

32

- 1 (4294967295). If the total I/O count reaches the

maximum value, it will re-start from 0.
To reset the

IO-Count

value to 0, execute the

dlnkmgr

command's

clear

operation. Executing the

clear

operation also resets the number of I/O errors

(

IO-Errors

) to 0. For details about the

clear

operation, see 6.2 clear (Returns

the Path Statistics to the Initial Value).

IO-Errors

#

-

Total I/O error count for the path, indicated by a decimal number. The maximum
value that can be displayed is 2

32

- 1 (4294967295). If the total I/O error count

reaches the maximum value, it will re-start from 0.
To reset the

IO-Errors

value to 0, execute the

dlnkmgr

command's

clear

operation. Executing the

clear

operation also clears the number of I/O

operations (

IO-Count

) to 0.

For details about the

clear

operation, see 6.2 clear (Returns the Path Statistics

to the Initial Value).

DNum

#

-

Dev number, where 0 (fixed) is displayed.
This item pertains to a partition number.

HDevName

#

-

Host device name.
The name of the logical device file (minus the partition number),

/dev/

sddlm

[aa-pap], for the HDLM device.

For details on logical device files for HDLM devices, see 2.6 Logical Device

Files for HDLM Devices.

IEP

#

-

Information about the intermittent error.
This item is displayed only when you specify

-iem

with the

-path

parameter.

One of the following values is displayed for each path:

-

Indicates that intermittent error monitoring is disabled or the monitoring time
for an intermittent error is out of range.

A value of at least 0

Indicates the number of errors that occurred during intermittent error

monitoring.

*

Indicates that an intermittent error occurred (automatic failbacks do not

check the path).

HBAPortWW

N

#

-

A 16-digit hexadecimal number indicating the WWN information for an HBA
connected to the storage system. This item is displayed only when you specify

-iem

together with the

-hbaportwwn

parameter.

For an iSCSI interface, a hyphen (

-

) is displayed.

Displayed Item

Description

No

summary

displayed

Summary
displayed

This manual is related to the following products: