beautypg.com

Seed Hawk Raven 2012 User Manual

Page 56

background image

Chapter 4

44

Seed Hawk® Viper Pro™ Installation & Operation Manual

Base Systems

The following procedure contains information for configuring section widths for Seed Hawk Base systems. See
the SCT™ Systems section on page 45 for information on the Section Width Setup screen for systems with the
SCT system installed.

1.

Base systems will control products 1 through 3 across the implement width. To ensure proper rate control of
these products, enter the implement width as the section 1 width value.

Note:

In a Base system, the first section must always set to the full drill width and is assigned to products
1 through 3 applied from the air cart. The section 1 switch on the Seed Hawk switch box toggles all
of the air cart bins simultaneously for the entire drill width.

2.

Optional liquid products may be controlled in up to four sections. To configure the remaining section widths,
divide the total implement width by the number of remaining sections.

Note:

To change the number of configured sections, touch the Prev button to go back to the Drill Setup
screen. See Chapter 9, Sectional Control Technology™ (SCT) for more information on SCT and
Base systems.

3.

Touch the OK button to accept the programmed settings and return to the Viper Pro main screen.

This manual is related to the following products: