Product control settings area for products 1-3 – Seed Hawk Raven 2012 User Manual
Page 144
![background image](/manuals/364509/144/background.png)
Chapter 8
132
Seed Hawk® Viper Pro™ Installation & Operation Manual
Product Control Settings Area for Products 1-3
The Product Control Settings area displays an overview of the following calibration settings and values used by
the control system to monitor or adjust the rate of product application:
Note:
The following sections offer descriptions of the various options and settings used with products 1
through 3. For descriptions of the settings used with products 4 and 5, see the Product Control
Settings Area for Products 4-5 section on page 135.
The following data displays are shown in the Product Control Settings area for reference and monitoring
purposes only:
Area/Hour. Displays the current area per hour covered during product application. This value is calculated
using the programmed section set up and the vehicle speed.
Vol/Min. Displays the current volume per minute monitored by the selected product node or control channel
during active application. This value is calculated using the flow of product monitored by the flow meter.
PWM. Displays the current duty cycle of the PWM valve controlling product application (if applicable).
To modify product control settings for the above features, touch within the product control settings area on the
CAN Controller Status screen.
Note:
Before changing any of the product control settings, be sure to select the correct product node or
control channel by touching the corresponding radio button displayed at the top of the feature
settings area.
•
Area/Hour (Display only)
•
Meter Cal
•
Pre Set PW
•
Vol/Min (Display only)
•
Valve Cal
•
PW Freq
•
Rate Cal
•
Min PW
•
Valve Delay
•
Rate Bump (+/-)
•
Max PW
•
PWM (Display only)
Status Screen Example
(Products 1-3)