beautypg.com

Error messages, General error messages setup error messages – Seed Hawk Raven 2012 User Manual

Page 229

background image

Manual No. 016-3001-003

217

Troubleshooting the Viper Pro System

13

Error Messages

The following table provides issues and solutions about error messages displayed on the Viper system.

General Error Messages

Setup Error Messages

Issue

Possible Cause

Solution

The Activation key is
not valid

• Incorrect Activation key

entered

• Re-enter the Activation key. If this still does not work,

contact a local Raven representative.

Scout file error

• Scout file for one of the

jobs is missing

• Press OK to bypass.

• File is an older version

and not compatible with

the current software

release

• Press OK to bypass.

JobMap error

• Scout file for job is

missing

• Press OK to bypass and create a scout file for the

current job.

Issue

Possible Cause

Solution

Sections must be
specified in left-to-
right order

• Sections are not

configured sequentially in

a left-to-right order

• Configure the sections in a left-to-right order. See

Section Setup Wizard section on page 164 for more

information on configuring sections.

There is a gap or
overlap between
section sections

• Improper values entered

into either section widths

and/or the left/right

values for individual

section sections.

• Check the section setup values entered for Left/Right,

and check the sections set up for this product. Set up

section sequentially from left-to-right. Left/Right value is

measured from center of section.

• Section select functions

not properly configured.

• Section select must specify individual sections for

individual products if a gap or overlap is detected.

Missing Scout File

• Scout files have been

deleted from the scout

folder but other folders

contain files associated

with the job.

• Delete all files with the same name from all the other

folders on the flash drive if the specified job name is not

necessary for the job in progress. Use the File

Maintenance function to delete the remaining files.

Make sure to keep a backup on a home or office PC if

the job will be needed at a later date.

Rx Colors error.
"You must enter a
name for this
template"

• The custom RxMap

Colors was selected but

no name was given to the

template

• Enter a name for the custom Rx Color template.

RxColor error. "You
must pick a color for
entry Minimum"

• There is no color

selected for the range

• Press Select and select a color for the minimum level.

Could not grow
buffer

• Streetmaps that are

being installed are too

large for the Viper system

memory

• Limit streetmaps to four counties or less, depending

upon the file size. More densely populated counties

have a larger file size than sparsely populated counties.

This manual is related to the following products: